NEW QUESTION 46
What is a limitation when creating a server profile?
- A. ILO management is limited to the integration with Active Directory or LDAP
- B. Administrator cannot define more than 8 connections within a server profile
- C. BIOS settings can be changed only when UEFI optimized is selected as boot mode
- D. It is not possible to create shared volumes on demand through a server profile
Answer: A
NEW QUESTION 47
Click the option that will allow you to change the ESXI image used In an OS Deployment Plan.
Answer:
Explanation:
NEW QUESTION 48
Click the option that will allow you to change the ESXI image used In an OS Deployment Plan.
Answer:
Explanation:
NEW QUESTION 49
Match HPE SimpliVity team with the definition.
Answer:
Explanation:
NEW QUESTION 50
Refer to the exhibit.
Which statement about this logical JBOD is true?
- A. This logical JBOD can be presented to the compute nodes in a different frame.
- B. After deleting this logical JBOD drives will he blocked for 12h m case this JBOD must be re-created
- C. This logical JBOD can be connected to multiple systems to formulate a snared datastore.
- D. After deleting this logical JBOD, its drives w not be available until a clean-up procedure 6 done
Answer: D
NEW QUESTION 51
Your customer manages an HPE Synergy platform using HPE OneView 5.6. To leverage new functionalities, the customer wants to update HPE OneView to version 61 Which statement about this update process is true?
- A. Before updating to 6,1, customer should increase memory size on the HPE Composer.
- B. The customer must check the HPE Composer version, as 61 is supported only with HPE Composer2.
- C. The customer can update directly to 6,1, but HPE OneView downtime will be longer.
- D. To update to 6,1, the customer has to first update to 6 0, which is a milestone edition.
Answer: B
NEW QUESTION 52
Refer to the exhibit.
Which statement about this logical JBOD is true?
- A. This logical JBOD can be presented to the compute nodes in a different frame.
- B. After deleting this logical JBOD drives will he blocked for 12h m case this JBOD must be re-created
- C. This logical JBOD can be connected to multiple systems to formulate a snared datastore.
- D. After deleting this logical JBOD, its drives w not be available until a clean-up procedure 6 done
Answer: D
NEW QUESTION 53
Your customer reports that they cannot deploy HPE Synergy compute nodes using HPE OneView for VMware vCenter Server (HPE OV4VC).
What should you check during troubleshooting process?
- A. If the HPE Oneview instance Is integrated with HPE OV4VC.
- B. If an compute nodes are added to the vCenter Server
- C. If vCenter Server is licensed in the HPE Oneview interface
- D. If HPE OneView credentials are added in vCenter Server
Answer: B
NEW QUESTION 54
Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They plan to use Distributed Switches and DRS cluster You are preparing a proposal with the following components:
- HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules
- two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
- an appropriate number of the vSphere Standard licenses for each compute node
- one HPE D3940 Storage Modules with 40 SSDs - all required cables and options Which statement about this proposal is true?
- A. One HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50GD/S ILM
- B. 20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drive.
- C. vSphere Standard licenses should be replaced with Enterprise Pius licenses to enable requested features
- D. 2 additional HPE Synergy 480 Gen10 Plus compute modules can be added to this setup
Answer: C
NEW QUESTION 55
Your customer has an HPE Synergy platform deployed and managed using HPE OneView. The customer also has HPE Superdome Flex with RMC deployed They plan to deploy a second nPar and HPE Superdome Flex 280 They plan to manage new components using HPE OneView What must be done to achieve this goal?
- A. The customer must add a second Rack Management Controller for HPE Superdome Flex 280
- B. The customer should deploy an HPE OneView appliance for HPE Superdome Flex management
- C. The customer has to add HPE Superdome Flex to the HPE OneView used to manage HPE Synergy
- D. The customer must use IL05 to add HPE Superdome Flex systems to HPE OneView
Answer: A
NEW QUESTION 56
Your customer has an HPE Synergy frame equipped with a D3940 Storage Module. Each of the compute nodes has an appropriate storage controller Installed and two 12Gb SAS switches installed in the first fabric.
The customer reports that compute nodes cannot access the storage module. What should you verify first when troubleshooting this problem?
- A. If the D3940 storage module is property licensed through HPE OneView interface.
- B. If there is at least one ISCSI network configured that will provide access to the module.
- C. If the D3940 module is imported in managed state that allows volume provisioning.
- D. If there Is a logical interconnect created based on the 12Gb SAS switches.
Answer: C
NEW QUESTION 57
Your customer has a logical enclosure configured using a angle HPE Synergy frame with the following configuration
- two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
- two HPE Synergy Virtual Connect SE 32Gb FC Modules -12 HPE Synergy 480 Gen10 Plus compute nodes with appropriate mezzanine cards They plan to add a new HPE Synergy frame to an existing logical enclosure with the following configuration
- two HPE Synergy Virtual Connect SE 32Gb FC Modules
- two HPE Synergy 20Gb interconnect Link Modules
- Eight HPE Synergy 480 Gen 10 Plus compute nodes with appropriate mezzanine cards Which statement about the planned configuration change is true?
- A. A license for an extended logical enclosure must be added to HPE OneView through GUI
- B. The HPE Synergy virtual Connect SE 32Gb FC Modules from both frames should be stacked
- C. The two HPE Synergy 20Gb interconnect Link Modules must be replace with the 50Gb option
- D. Four compute modules must be moved to the second frame to balance the configuration
Answer: B
NEW QUESTION 58
Which statement about the SY480 Gen10 Plus Compute Module is true?
- A. It supports "3rd Gen AMO EPYC Server Processors with 64 cores.
- B. It supports 8 memory channels and memory DIMMs of up to 256GB.
- C. It only supports NVDIMM Persistent Memory.
- D. It cannot be mixed with Gen9 compute modules in the same frame.
Answer: C
NEW QUESTION 59
Match HPE SimpliVity team with the definition.
Answer:
Explanation:

NEW QUESTION 60
Your customer plans to deploy VMware vSAN using D3940 Storage Modules.
Which statement about this solution is true?
- A. The 12Gb SAS modules required for D3940 connectivity can only be installed in the first fabric.
- B. To use the storage controller that will access D3940 storage modules, a second CPU must be installed.
- C. For VMware vSAN deployment, all drives in the D3940 storage modules must be SSD drives.
- D. All drives in the D3940 storage modules must formulate a single logical drive with RAID5 configured
Answer: A
NEW QUESTION 61
Match each HPE Synergy logical component with the definition.
Answer:
Explanation:

NEW QUESTION 62
Which tool can be used to evaluate me health of an HPE Oneview appliance before proceeding with an appliance updated.
- A. HPE Composer Maintenance Console
- B. HPE OneView Firmware Compliance Report
- C. HPE OneView Global Dashboard
- D. HPE OneView Update Readiness Checker
Answer: A
NEW QUESTION 63
Your customer used to manage their HPE 3PAR arrays using HPE OneView Now they have replaced these arrays HPE Primera.
How does managing the new arrays compare to managing their old arrays?
- A. To manage HPE Primera using HPE OneView. a dedicated license is required
- B. Management procedures and features are the same tor both types of the array
- C. HPE OneView offers limited support tor HPE Primera because of the firmware differences
- D. HPE OneView offers additional functionalities for HPE Primera like CPG management
Answer: D
NEW QUESTION 64
Your customer wants to add dedicated Fibre Channel connectivity to the HPE Synergy frame running HPE Synergy 480 Gen10 compute modules, each with one CPU socket populated Currently they use two 12 Gb SAS switches and two HPE Virtual Connect SE 100Gb F32 Modules for HPE Synergy installed in third fabric.
What must be done to enable dedicated FC connectivity for this HPE Synergy frame?
- A. For VC-FC modules, all of server facing ports must be property licensed.
- B. For Brocade switches, a logical interconnect group must be created in HPE OneView.
- C. SAS switches must be moved to second fabric and FC modules Installed in the first one.
- D. A second CPU must be installed for all HPE Synergy 480 Gen10 compute nodes.
Answer: C
NEW QUESTION 65
Your customer added a new Ethernet network in HPE Oneview mat is used to manage their HPE Synergy platform.
When the customer tries to connect one of the compute nodes to this network through the server profile, this network is not available.
What must be done to fix this issue?
- A. To make this network available to use in the server profile, the customer must enable the Smart Link feature within network definition.
- B. Check within the server profile which server hardware is used and perform the Refresh operation on this compute node to get the latest adapter information.
- C. Check the Logical Enclosure settings and verify if the maximum number of networks allowed for this LE is reached.
- D. The newly created network must be added to the uplink set within the LIG, and Logical interconnect configuration must be updated from the LIG.
Answer: D
NEW QUESTION 66
Your customer has me following HPE Synergy setup
- Three frames fully populated with HPE Synergy 480 Gen10 Plus modules and 25Gb/s downlink speed formulating a single logical enclosure
- Two HPE Virtual Connect SE 100Gb F32 Module for Synergy
- Four HPE Synergy 50Gb interconnect Link Module
- Six HPE Synergy Virtual Connect SE 32Gb FC Modules
The customer needs to add a frame.
Which statement about the expansion of this setup is true?
- A. The additional frame must have HPE Virtual Connect FC modules installed
- B. The additional frame cannot have 12Gb SAS connection modules installed
- C. The customer has to create a new logical enclosure for the additional frame
- D. The customer can grow the existing logical enclosure up to 5 frames
Answer: C
NEW QUESTION 67
You modified a logical interconnect group mat is used to configure logical interconnects in five different logical enclosures. What will be the impact of that change?
- A. All physical interconnects from affected logical interconnects will be placed in a maintenance mode
- B. All logical interconnects configured using this logical interconnect group will be automatically updated
- C. All physical interconnects from the affected logical interconnects must he rebooted to activate the new configuration
- D. All logical interconnects configured using this logical Interconnect group will report inconsistency
Answer: A
NEW QUESTION 68
Which statement about HPE Superdome nPars is true?
- A. Rack Management Controller is required Tor nPar configuration
- B. Chassis in the same nPar can have different memory configuration
- C. Chassis in the same nPar can have different CPU configuration
- D. nPars are supported only with 3rd Generation Intel Xeon Scalable Processors
Answer: A
NEW QUESTION 69
......
HP HPE0-S60 Exam Syllabus Topics:
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
Earn Quick And Easy Success With HPE0-S60 Dumps: https://freedumps.testpdf.com/HPE0-S60-practice-test.html